© Copyright 2020 TRENDnet. All Rights Reserved.
TRE
NDnet User’s Guid
e
TPE-3012LS / TPE-3018LS
126
Save DHCP Snooping Database
Security > IP Source Guard > Save Database
This page allow user to configure DHCP snooping database which can backup and
restore dynamic DHCP snooping entries.
1. Log into your switch managem
ent page (see “
Access your switch management page
on page 11).
2. Click on
Security,
click on
IP Source Guard,
and click on
Save Database
.
3. Review the settings below.
Item
Description
Type
Select the type of database agent.
•
None: Disable database agent service.
•
Flash: Save DHCP dynamic binding entries to flash.
•
TFTP: Save DHCP dynamic binding entries to remote TFTP
server.
Filename
Input filename for backup file. Only available when
selecting type
“flash” and “TFTP”.
Address
Type
Select the type of TFTP server.
•
Hostname: TFTP server address is hostname.
•
IPv4: TFTP server address is IPv4 address
Server
Addres
Input remote TFTP server hostname or IP address. Only
available when selecting type
“TFTP”
Write Delay
Input delay timer for doing backup after change happened.
Default is 300 seconds.
Timeout
Input aborts timeout for doing backup failure. Default is
300 seconds.
4. Click
Apply
.
5. In the top right, click
Save
to save the configuration settings to NV-RAM/startup
configuration.
6. Click
OK
.
Summary of Contents for TPE-3012LS