23
or
switch#show aggregator 3
no aggregator lacp
[GroupID]
G
Disable the LACP
function of trunk group
switch(config)#no aggreator lacp
1
no aggregator group
[GroupID]
G
Remove a trunk group switch(config)#no aggreator
group 2
VLAN Commands Set
Netstar Commands
Level Description
Example
vlan database
P
Enter VLAN configure
mode
switch#vlan database
Vlanmode
[portbase| 802.1q |
gvrp]
V
To set switch VLAN
mode.
switch(vlan)#vlanmode portbase
or
switch(vlan)#vlanmode 802.1q
or
switch(vlan)#vlanmode gvrp
no vlan
V
No VLAN
Switch(vlan)#no vlan
Ported based VLAN configuration
vlan port-based
grpname
[Group Name]
grpid
[GroupID]
port
[PortNumbers]
V
Add new port based
VALN
switch(vlan)#vlan port-based
grpname test grpid 2 port 2-4
or
switch(vlan)#vlan port-based
grpname test grpid 2 port 2,3,4
show vlan
[GroupID]
or
show vlan
V
Show VLAN
information
switch(vlan)#show vlan 23
no vlan group
[GroupID]
V
Delete port base group
ID
switch(vlan)#no vlan group 2
IEEE 802.1Q VLAN
Summary of Contents for Milan MIL-SM8002TG
Page 23: ...15 Console login interface...
Page 65: ...57 Security Manager interface...
Page 79: ...71 Group Remove interface Group List Display the all VLAN groups information...
Page 96: ...88 SNMP v3_Group Table interface Access Table Configure SNMP v3 access table...
Page 98: ...90 Remove Browse Table Remove and Browse access table...
Page 99: ...91 MIBview Table Configure MIB view table...
Page 101: ...93 Remove Browse Table Remove and Browse MIBview table...
Page 123: ...115 Reboot System interface...
Page 160: ...152 SNMP V3 configuration interface Group Table Configure SNMP v3 group table...
Page 163: ...155 QoS Configuration interface Port Base Priority...