EO2P User Guide |Page 25
33706 Rev. A
IP page Buttons
Ok
: Click the
Ok
button to accept the current page parameter changes.
Cancel
: Click the
Cancel
button to negate the current page parameter changes and
revert to the default parameter settings.
Log Out
: Click the
Log Out
button to exit EO2P Web Configuration.
IP Addressing Note
: EO2P units are intended to be fully managed through a single
IP address. Note that two IP addresses will always be present but the IP address in
the Remote unit can remain the default 192.168.0.2 and typically not impact
network addressing while the IP address in the Local unit can be user-defined.
The following operations and settings cannot be performed on the Remote unit
using the Web interface on the Local unit:
1) Hardware reset (can be done using the
RESET
buttons, or can be done by logging
in to the Remote unit directly).
2) Factory default reset (can be done using the
RESET
buttons, or can be done by
logging in to the Remote unit directly).
3) Security pairing and unpairing (can be done using the
RESET
buttons).
4) Ethernet Link Settings, SFP Detection Setting, and Primary Link (can only be done
by logging in to the Remote unit directly).