Programming Codes
T480
Programmer’s Guide
Page
90
Rev A
100-14362
[ESC] g <0> Process user macro
ASCII
[ESC] g <0>
Hexadecimal
1BH 67H 00H
Decimal
<27> <103> <0>
IPCL
&%GP
EPOS
[ESC] g <0>
Description
The [ESC] g <0> command prints the user-store data buffer.
[ESC] g <1> Start macro record
ASCII
[ESC] g <1>
Hexadecimal
1BH 67H 01H
Decimal
<27> <103> <1>
IPCL
&%GS
EPOS
ESC] g <1>
Description
The [ESC] g <1> command clears the user-store data buffer and begins
recording data. The next 2000 bytes (including characters and commands) are
recorded.
[ESC] g <2> Stop macro record
ASCII
[ESC] g <2>
Hexadecimal
1BH 67H 02H
Decimal
<27> <103> <2>
IPCL
&%GE
EPOS
[ESC] g <2>
Description
The [ESC] g <2> command stops recording user-store data information.
The buffer is not saved into the nonvolatile memory.
[ESC] g <3> Stop macro record and save
ASCII
[ESC] g <3>
Hexadecimal
1BH 67H 03H
Decimal
<27> <103> <3>
IPCL
&%GW
EPOS
[ESC] g <3>
Description
The [ESC] g <3> command stops recording graphic save information.
The buffer is saved into the user-store nonvolatile memory under the name,
"ESCg3_Save"
Note:
The [ESC] g <3> command is supplied for compatibility with the
Series 80PLUS and 90PLUS printers.