Programming Codes
T480
Programmer’s Guide
Page
154
Rev A
100-14362
Maxicode Print Options
Function
Maxicode control
ASCII
[ESC] [EM] m <f> <v>
Hexadecimal
1BH 19H 6DH <f> <v>
Decimal
<27> <25> <109><f> <v>
IPCL
None
Description
This command alters the way Maxicode barcodes are generated and
printed.
Where
f = Feature to control and v = the value of the feature.
f = W 57H, 87D
Set Scale. The scale may be set from 0 to 10, however,
only values of 8, 6, 4, and 2 will be used. (default is 4)
(0 will default to 4 and odd numbers will round down.)
A scale of 2 may be unreadable.
It the barcode will not fit in the print zone, the printer will
automatically reduce the scale until the barcode will fit. If
the barcode will not fit at a width of 1, the printer will not
print the barcode.
f = H, 48H, 72D
Blank Space between the barcode and the following data
Default 8
f = M, 4DH, 77D
Mode 2, 3, 4 and 5 are accepted, 0 = Auto
f = P, 50H, 80D
HRI Position
f =0
– Off, f = 1 - Top, f =2 - Bottom, f =3 - Both
f = F, 46H, 70D
HRI Font
f = 0 Medium, f=1 Larger, f- 2 Smaller (Note: Fonts may be
redefined by using the change legacy font command.)