Epic 3000
Programmer’s Guide
Programming Codes
100-14362
Rev A
Page 157
Databar (RSS) Print Options
Function
Databar Options
ASCII
[ESC] [EM] r <f> <v>
Hexadecimal
1BH 19H 72H <f> <v>
Decimal
<27> <25> <114><f> <v>
IPCL
None
Description
This command alters the way Databar barcodes are generated and
printed.
Where
f = Feature to control and v = the value of the feature.
f = W 57H, 87D
Set the minimum element width.
v = 1-10, 3 is the default.
A width of 1 may be unreadable.
It the barcode will not fit in the print zone, the
printer will automatically reduce the width until the
barcode will fit. If the barcode will not fit at a width
of 1, the printer will not print the barcode.
f = S, 53H, 83D
Expanded Stack character segment width.
v = 2-10 Default 3
f = K, 4BH, 75D
Activate Stacked symbol HRI. 0 = off, 1 = on.
By convention stacked barcode are not printed with
HRI, however if required they may be activated
f = G, 47H, 71D
GS1 Mode. Default = 0x19
(See General description above)
By default Databar barcodes use GS1 formatting.