Programming Codes
T480
Programmer’s Guide
Page
86
Rev A
100-14362
IPCL
&%UC <Name..><0>
EPOS
[GS] 6
<
Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] c <Name..> <0> command saves the current user-
defined character structure in the flash user-save storage area. It uses the<Name..>
field as a reference. If the name already exists in the flash user store, the command will
not store the data.
The terminating <0> may be replaced with an & or redefined. See [ESC] [EM]T<n> or
&%UT<n> on page 88.
Function
Load item from user store
ASCII
[ESC] [US] l <Name..> <0>
Hexadecimal
1BH 1FH 6CH
Decimal
<27> <31> <108>
IPCL
&%UL <Name..> <0>
EPOS
[GS] 0<Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] l <Name..> <0> command loads the referenced item into
the appropriate structure. If the item referenced is a user-defined character set, it is
loaded into the current user-character definition, which does not affect the active state of
user-defined characters. If it is a macro, it is loaded into the macro buffer, but it is not
inserted into the data stream. [ESC] g <0> inserts the macro buffer into the data stream.
If the named item does not exist, the command does nothing.
The terminating <0> may be replaced with an & or redefined. See [ESC] [EM]T<n> or
&%UT>n> on page 88.
Function
Run macro data from user store
ASCII
[ESC] [US] r <Name..> <0>
Hexadecimal
1BH 1FH 72H
Decimal
<27> <31> <114>
IPCL
&%UR <Name..> <0>
EPOS
[GS] 0
<
Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] r <Name..> <0> command loads the referenced macro
into the macro buffer. The macro buffer is then inserted into the data stream. If the
named item does not exist or is not a macro, nothing happens.
The terminating <0> may be replaced with an & or redefined. See [ESC] [EM]T<n> or
&%UT<n> on page 88.
Function
Flag item as a start-up macro
ASCII
[ESC] [US] s <Name..> <0>
Hexadecimal
1BH 1FH 73H
Decimal
<27> <31> <115>
IPCL
&%US <Name..> <0>
EPOS
[GS] 0
<
Name..> <0> is from one to 15 characters and must be null
terminated.
Description
The [ESC] [US] s <Name..> <0> command flags the referenced item to
be processed at startup. Only one user character definition and one macro may be
flagged to run at startup.