E6581158
K-1
11
11. Table of parameters and data
11.1
User parameters
Title
Function
Unit
Minimum
setting unit
Panel/Comm
unication
Adjustment range
Default setting
User
setting
Refer-
ence
HE
Operation fre-
quency of opera-
tion panel
Hz
0.1/0.01
NN
-
WN
0.0
3.2
11.2
Basic parameters
•
Four automatic functions or basic parameters
Title
Communication
No.
Function
Unit
Minimum
setting unit
Panel/Commun
ication
Adjustment range
Default
setting
User
setting
Reference
CWJ
-
History function
-
-
Displays parameters in groups of five
in the reverse order to that in which
their settings were changed.
* (Possible to edit)
-
4.1.4
CW
0000
Automatic
acceleration/decel
eration
-
-
0: Disabled (manual)
1: Automatic
2: Automatic (only at acceleration)
0
5.1.1
CW
0001
Automatic torque
boost
-
-
0: Disabled
1: Automatic torque boost + auto-
tuning
2: Vector c auto-tuning
3: Energy auto-tuning
0
5.2
CW
0040
Automatic function
setting
-
-
0: Disabled
1: Coast stop
2: 3-wire operation
3: External input UP/DOWN setting
4: 4-20 mA current input operation
0
5.3
EOQF
0003
Command mode
selection
-
-
0: Terminal board
1: Operation panel
1
5.4
HOQF
0004
Frequency setting
mode selection 1
-
-
0: Built-in potentiometer
1: VIA
2: VIB
3: Operation panel
4: Serial communication
5: UP/DOWN from external contact
6: VIA + VIB (Override)
0
5.4
6.5.1