1) Auto-restart after momentary power failure (Auto-restart function)
Input voltage
Motor speed
F-CC
ON
OFF
+
Setting
H
to
, (
): This function operates after power has been restored following detection of an
undervoltage by the main circuits and control power.
2) Restarting motor during coasting (Motor speed search function)
Motor speed
F-CC
ON
OFF
ST-CC
ON
OFF
+
Setting
H
to
ҏ
or
: This function operates after the ST-CC terminal connection has been opened
first and then connected again.
Note:
The terminal function ST needs to be assigned to an input terminal, using the parameters
H
to
H
.