E6581158
F-79
6
Q
Example of setting 2
When
H
=1.00 (Hz), and
H
=1:
Each time you press the
▲
▲
▲
▲
key, the frequency setting
HE
changes in steps of 1Hz: 0
→
1
→
2
→
...
→
60
(Hz) and also the value displayed on the operation panel changes in steps of 1. Use these settings to hide
decimal fractions and also the value displayed on the operation panel changes in steps of 1. Use these
settings to hide decimal fractions.
6.21.5 Changing the item displayed by default
H
: Standard monitor display selection
•
Function
This parameter specifies display format while power is on.
Q
Changing the display format while power is on
When the power is on, the standard monitor mode displays the operation frequency (default setting) in the
format of "
" or "
QHH
". This format can be changed to any other monitor display format by setting
H
. This new format, however, will not display an assigned prefix such as
V
or
E
.
Š
Parameter setting
Title
Function
Adjustment range
Default setting
H
Standard monitor display
selection
0: Operation frequency (Hz/free unit/step)
1: Frequency command (Hz/free unit/step)
2: Output current (%/A)
3: Inverter rated current (A)
4: Inverter load factor (%)
5: Output power (kW)
6: Frequency command after PID control
(Hz/free unit/step)
7: Optional item specified from an external
control unit
0
,
For more information on the
H
option “
,” refer to “Communications Function Instruction Man-
ual.”