E6581158
F-15
6
6.4
Basic parameters 2
6.4.1 Switching motor characteristics via terminal input
H
: Base frequency 2
H
: Base frequency voltage 2
H
: Torque boost 2
H
: Motor electronic-thermal protection level 2
H
: Stall prevention level 2
•
Function
Use the above parameters to switch the operation of two motors with a single inverter and to select
motor V/F characteristics (two types) according to the particular needs or operation mode.
Note: The
RV
(V/F control mode selection) parameter is enabled only for motor1.
If motor 2 is selected, V/F control will be given constant torque characteristics.
Q
Parameter setting
Title
Function
Adjustment range
Default setting
H
Base frequency 2
25.0-500.0 (Hz)
50.0 (WP type)
60.0 (WN, AN type)
H
Base frequency voltage 2
50-660 (V)
200 (200V class) / 400
(400V class)
H
Torque boost 2
0.0-30.0 (%)
According to model
(See Section 11, K-14)
H
Motor electronic-thermal protection level 2
10-100 (%)
100
H
Stall prevention level 2
10-199 (%)
200 : Disabled
150