E6581158
D-8
4
Q
How to use the history function
Key operated
LED display
Operation
Displays the operation frequency (operation stopped).
(When standard monitor display selection
H
=
[Operation
frequency])
CWJ
The first basic parameter “
CWJ
” (history function) is displayed.
CEE
The parameter that was set or changed last is displayed.
Press the ENTER key to display the set value.
Press the key and key to change set value.
⇔
CEE
Press the ENTER key to save the changed value. The parameter
name and the programmed value will flash on and off alternately.
****
Use the same steps as those given above to display parameters that
you want to search for or change setting with the key and key.
JGCF
(
GPF
)
JGCF
: First historic record
GPF
: Last historic record
Parameter
display
↓
CWJ
↓
HTH
↓
Press the MODE key to return to the parameter setting mode
“
CWJ
.”
After that you can press the MODE key to return to the status moni-
tor mode or the standard monitor mode (display of operation fre-
quency).
MODE
MODE
MODE
MODE