4.1.6 Returning all parameters to standard default setting
Setting the standard default setting parameter
V[R
=
, all parameters can be returned to the those factory
default settings.
Note: For more details on the standard default setting parameter
V[R
, see 5.6.
Notes on operation
•
We recommend that before this operation you write down on paper the values of those parameters,
because when setting
V[R
=
, all parameters with changed values will be returned to standard fac-
tory default setting.
•
Note that
HO
,
HOUN
,
H
,
H
and
H
will not be reset to their factory default set-
tings.
Q
Steps for returning all parameters to standard default setting
Key operated
LED display
Operation
Displays the operation frequency (perform during operation stopped).
CWJ
The first basic parameter “
CWJ
” (history function) is displayed.
V[R
Press the key or the key to change to
V[R
.
Pressing the ENTER key displays the programmed parameters.
(
V[R
will always display "
(zero)" on the right, the previous setting
on the left.)
Press the key or the key to change the set value.
To return to standard factory default setting, change to "
".
KPKV
Pressing the ENTER key displays "
KPKV
" while returning all
parameters to factory default setting.
The monitor returns to the display of setup parameters.
If there is anything you do not understand during this operation, press the key several times to
start over from the step of
CWJ
display.