E6581158
J-9
10
Fig. A
Fig. B
Fig. C
PA/+
DC reactor
Power source
4.5 x 6 slotted hole (DCLS-2002)
4.4 x 6 slotted hole (DCL-2007)
Name plate
Terminal box
with cover
Name plate
Terminal box
with cover
Name
plate
Devices
External dimensions and connections
DC reactor
Dimensions (mm)
Model
Rated
current
(A)
Inverter type
W
H
D
X
Y
d1
D2
Di
a
g
ra
m
Terminals
Approx.
weight
(kg)
DCLS-2002
2.5
VFS11-2002PM
VFS11S-2002PL (Note 1)
79
50
44
66
-
-
-
Crimp terminal
V1.25-3.5
0.6
DCL-2007
7
VFS11-2004
∼
2007PM
VFS11S-2004PL (Note 1)
92
65
70
82
-
-
-
A
Crimp terminal
V2-3.5
1.2
DCL-2022
14
VFS11-2015, 2022PM
VFS11S-2007PL (Note 1)
86
110
80
71
64
-
-
M4
2.2
DCL-2037
22.5
VFS11-2037PM
VFS11S-2015, 2022PL (Note 1)
86
110
85
71
70
-
-
B
M4
2.5
DCL-2055
38
VFS11-2055PM
75
130
140
50
85
85
55
M5
1.9
DCL-2110
75
VFS11-2075
∼
2110PM
100
150
150
65
85
95
55
M6
2.4
DCL-2220
150
VFS11-2150PM
117
170
190
90
90
130
60
C
M8
4.3
DCL-2007
7
VFS11-4004
∼
4015PL (Note 2)
92
65
70
82
-
-
-
A
Crimp terminal
V2-3.5
1.2
DCL-2022
14
VFS11-4022, 4037PL (Note 2)
86
110
80
71
64
-
-
B
M4
2.2
DCL-4110
38
VFS11-4055
∼
4110PL
95
150
165
70
90
105
60
M5
3.0
DCL-4220
75
VFS11-4150PL
105
160
185
80
100
130
65
C
M8
3.7
Note 1:
Connecting this reactor to the inverter makes it compliant with the standard "General
Inverter (input current of 20A or less) Harmonic Suppression Measures Execution
Guidelines" set by the Japan Electric Industry Association.
Note 2:
Use 200V class for VFS11-4004PL-4037PL DC reactor.