2.3 Power Supply Troubleshooting
2 Troubleshooting Procedures
QOSMIO G40 Maintenance Manual (960-632)
[CONFIDENTIAL]
2-15
AMP-PFV output
Error code
Meaning
E0h
AMP-PFV voltage is over 13.26V.
E1h
AMP-PFV voltage is under 9.392V when the computer is powered on.
E2h
AMP-PFV voltage is under 9.392V when the computer is booting up.
Miscellaneous
Error code Meaning
F0h
The sub clock does not oscillate.
Check 2 In the case of error code 10h or 12h:
Make sure the AC adapter and AC power cord are firmly plugged into the DC
IN 15 V socket and wall outlet. If the cables are connected firmly, go to the
following step.
Connect a new AC adapter and AC power cord. If the problem still occurs, go
to Procedure 5.
Check 3 In the case of error code 21h:
Go to Procedure 3.
Check 4 For any other errors, go to Procedure 5.