2.3 Power Supply Troubleshooting
2 Troubleshooting Procedures
QOSMIO G40 Maintenance Manual (960-632)
[CONFIDENTIAL]
2-9
Table 2-2 DC IN icon
DC IN icon
Power supply status
Lights blue
DC power is being supplied from the AC adapter.
Blinks orange
Power supply malfunction
*1
Doesn’t light
Any condition other than those above.
*1 When the power supply controller detects a malfunction, the DC IN icon blinks
orange. It shows an error code.
When the icon is blinking, perform the following procedure.
1.
Remove the battery pack and the AC adapter.
2.
Re-attach the battery pack and the AC adapter.
If the icon is still blinking after the operation above, check the followings:
Check 1 If the DC IN icon blinks orange, go to Procedure 2.
Check 2 If the DC IN icon does not light, go to Procedure 3.
Check 3 If the battery icon does not light orange or blue, go to Procedure 4.
NOTE
: Use a supplied AC adapter G71C0002R710, G71C0002R810 (2-pin)/
G71C00067210, G71C00067110 (3-pin).
Downloaded from LpManual.com Manuals
Summary of Contents for Qosmio G40
Page 10: ...x CONFIDENTIAL QOSMIO G40 Maintenance Manual 960 632 Downloaded from LpManual com Manuals ...
Page 11: ... CONFIDENTIAL Chapter 1 Hardware Overview Downloaded from LpManual com Manuals ...
Page 41: ... CONFIDENTIAL Chapter 2 Troubleshooting Procedures Downloaded from LpManual com Manuals ...
Page 131: ... CONFIDENTIAL Chapter 3 Tests and Diagnostics Downloaded from LpManual com Manuals ...
Page 231: ... CONFIDENTIAL Chapter 4 Replacement Procedures Downloaded from LpManual com Manuals ...
Page 375: ... CONFIDENTIAL Appendices Downloaded from LpManual com Manuals ...