172
6
F
2
S
0
7
8
9
LCD AND BUTTON OPERATION INSTRUCTION
NORMAL
(DISPLAY OFF)
VIEW
METERING 1
( DISPLAY ON )
VIEW
RESET
METERING 2
( DISPLAY ON )
VIEW
LATEST FAULT *
( DISPLAY ON )
RESET
VIEW
AUTO SUPERVISON *
( DISPLAY ON )
RESET
VIEW
RESET
TRIP OUTPUT
ISSUED !
TRIP
( LED ON )
MANUAL
MODE
AUTO-
MODE 1
RELAY
FAILED !
ALARM
( LED ON )
AUTO-
MODE 2
PRESS ANY
BUTTON
EXCEPT FOR
"VIEW" AND
"RESET"
MENU
( DISPLAY ON )
1=RECORD
1=FAULT RECORD
2=EVENT RECORD
2=STATUS
1=METERING
2=BINARY INPUT&OUTPUT
3=RELAY ELELMENT
4=TIME SYNC SOURCE
5=CLOCK ADJUSTMENT
3=SETTING
(VIEW)
1=RELAY VERSION
2=DESCRIPTION
3=RSM COMMUNICATION
4=RECORD
5=STATUS
6=PROTECTION
7=BINARY INPUT
8=BINARY OUTPUT
9=LED
5=TEST
1=SWITCH
2=BINARY OUTPUT
3=TIMER
4=LOGIC CIRCUIT
1. PRESS ARROW KEY TO MOVE TO EACH DISPLAYED
ITEMS
2. PRESS "END" KEY TO BACK TO PREVIOUS SCREEN
*. "LATEST FAULT" AND "AUTO
SUPERVISION" SCREEN IS
DISPLAYED ONLY IF DATA
IS STORED
4=SETTING
(CHANGE)
3=DISTURBANCE RECORD
Same as SETTING (VIEW) menu
Summary of Contents for GRT100 Series
Page 142: ... 141 6 F 2 S 0 7 8 9 Appendix A Block Diagram ...
Page 144: ... 143 6 F 2 S 0 7 8 9 Appendix B Signal List ...
Page 159: ... 158 6 F 2 S 0 7 8 9 ...
Page 160: ... 159 6 F 2 S 0 7 8 9 Appendix C Variable Timer List ...
Page 162: ... 161 6 F 2 S 0 7 8 9 Appendix D Binary Output Default Setting List ...
Page 165: ... 164 6 F 2 S 0 7 8 9 ...
Page 166: ... 165 6 F 2 S 0 7 8 9 Appendix E Details of Relay Menu and LCD and Button Operation ...
Page 174: ... 173 6 F 2 S 0 7 8 9 Appendix F Case Outline Flush Mount Type Rack Mount Type ...
Page 179: ... 178 6 F 2 S 0 7 8 9 ...
Page 180: ... 179 6 F 2 S 0 7 8 9 Appendix G External Connections ...
Page 185: ... 184 6 F 2 S 0 7 8 9 ...
Page 200: ... 199 6 F 2 S 0 7 8 9 ...
Page 201: ... 200 6 F 2 S 0 7 8 9 Appendix J Return Repair Form ...
Page 205: ... 204 6 F 2 S 0 7 8 9 Customer Name Company Name Address Telephone No Facsimile No Signature ...
Page 206: ... 205 6 F 2 S 0 7 8 9 ...
Page 207: ... 206 6 F 2 S 0 7 8 9 Appendix K Technical Data ...
Page 220: ... 219 6 F 2 S 0 7 8 9 ...
Page 221: ... 220 6 F 2 S 0 7 8 9 Appendix M Symbols Used in Scheme Logic ...
Page 224: ... 223 6 F 2 S 0 7 8 9 ...
Page 225: ... 224 6 F 2 S 0 7 8 9 Appendix N Implementation of Thermal Model to IEC60255 8 ...
Page 228: ... 227 6 F 2 S 0 7 8 9 ...
Page 229: ... 228 6 F 2 S 0 7 8 9 Appendix O IEC60870 5 103 Interoperability and Troubleshooting ...
Page 241: ... 240 6 F 2 S 0 7 8 9 Appendix P Modbus Interoperability ...
Page 255: ... 254 6 F 2 S 0 7 8 9 ...
Page 256: ... 255 6 F 2 S 0 7 8 9 Appendix Q Inverse Time Characteristics ...
Page 259: ... 258 6 F 2 S 0 7 8 9 ...
Page 260: ... 259 6 F 2 S 0 7 8 9 Appendix R Failed Module Tracing and Replacement ...
Page 266: ... 265 6 F 2 S 0 7 8 9 Appendix S Ordering ...
Page 269: ... 268 6 F 2 S 0 7 8 9 3 1 Oct 2 2017 Republished under spin off company ...
Page 270: ......