ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 2
2.1.2
Service call
E71
ADF jam
Jam not reaching the original registration sensor:
The original fed from the original feeding tray does
not reach the original registration sensor.
P. 5-10
E72
Jam not reaching the read sensor: The original
does not reach the read sensor after it has passed
the registration sensor.
P. 5-10
E73
Stop jam at the exit sensor: The trailing edge of the
original does not pass the exit sensor after its lead-
ing edge has reached this sensor.
P. 5-11
E86
ADF jam access cover open: The ADF jam access
cover has opened during ADF operation.
P. 5-11
E87
ADF open jam: ADF has opened during ADF opera-
tion.
P. 5-12
Error code
Classification
Contents
Troubleshooting
C01
Drive system
related service call
Main motor abnormality: The main motor is not rotating
normally.
P. 5-13
C21
Scanning system
related service call
CIS unit initialization error
P. 5-14
C26
Peak detection error: Lighting of the exposure lamp
(white reference) is not detected when power is turned
ON.
P. 5-14
C41
Fuser unit related
service call
Thermistor or heater abnormality at power-ON: Abnor-
mality of service call the thermistor is detected when
power is turned ON or the temperature of the fuser roller
does not rise in a specified period of time after power is
turned ON.
P. 5-15
C43
Thermistor abnormality during warming up or in ready
status after abnormality judgment
P. 5-16
C44
Heater abnormality after abnormality judgment: The tem-
perature of the fuser roller has exceeded the range of
control (in this case, the main switch turns OFF automati-
cally) or does not even reach the range.
P. 5-17
C45
Thermistor abnormality during printing: Abnormality of the
thermistor is detected during printing.
P. 5-17
C55
F11
Optional communi-
cation related ser-
vice call
ADF I/F error: Communication error has occurred
between the ADF and the scanner
P. 5-20
C94
Other service call
Firmware update error: An error message appears when
firmware for e-STUDIO166/206 is updated on e-
STUDIO163/203 by mistake, and the power is turned
OFF and then back ON after the update.
P. 5-19
C97
Process related
service call
High-voltage transformer abnormality: Leakage of the
main charger is detected.
P. 5-19
CA1
Laser optical unit
related service call
Polygonal motor abnormality: The polygonal motor is not
rotating normally.
P. 5-18
CA2
H-Sync detection error: H-Sync detection PC board can-
not detect laser beams.
P. 5-18
F14
Other service call
Invalid backup counter: The value of the total counter is
inconsistent with that of the backup counter.
P. 5-19
Error code
Classification
Contents
Troubleshooting