TROUBLESHOOTING
5 - 19
5
5.1.10
Service call for others
[C94] Firmware update error
Check if the updated firmware is for the intended model. Re-update if it was the wrong firmware.
Note:
Note:
A C94 error message appears if the firmware for e-STUDIO166/206 is updated on e-
STUDIO163/203 by mistake. Remember that no error message not appears when the firmware
for e-STUDIO163/203 is updated on e-STUDIO166/206.
[C97] High-voltage transformer abnormality
(1) Is the main charger installed securely?
(2) Check if the spring of high-voltage supply contact point is deformed.
(3) Check if the needle electrode is broken or the main charger grid is deformed.
(4) Check if any foreign matters is on the needle electrode or the main charger grid.
(5) Is the transfer/separation charger installed securely?
(6) Check if the transfer/separation charger wire is broken or unhooked.
(7) Check if any foreign matter is on the transfer/separation charger wire.
[F14]
Invalid backup counter
Has the MAIN board been replaced?
l
YES
Download the counter value of the SRAM board to the MAIN board in
the setting mode (08-389).
NO
Has the SRAM board been replaced?
l
YES
Download the counter value of the MAIN board to the SRAM board in
the setting mode (08-388).
NO
1) Check if the connector CN2 on the SRAM board and the connector CN2 on the MAIN
board are securely connected.
2) Replace the SRAM board.
3) Replace the MAIN board.