© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 3
2
2.2
Self-diagnosis Modes
Note:
Note:
To enter the desired mode, turn ON the power while two digital keys designated to each mode
(e.g. [0] and [5]) are pressed simultaneously.
Fig. 2-1
*1 Turn OFF the power after using the self-diagnosis modes, and leave the equipment to the user.
Mode
For start
Contents
For exit
Display
Input check
mode
[0]+[3]+
[POWER]
Checks the status of input signals.
[POWER]
OFF/ON
Output check
mode
[0]+[4]+
[POWER]
Checks the status of output signals.
[POWER]
OFF/ON
Test print
mode
[0]+[7]+
[POWER]
Outputs the test patterns.
[POWER]
OFF/ON
Adjustment
mode
[0]+[5]+
[POWER]
Adjusts various items.
[POWER]
OFF/ON
Setting mode
[0]+[8]+
[POWER]
Sets various items.
[POWER]
OFF/ON
List print mode [9]+[START]
+[POWER]
Prints out the data lists of the codes 05/08 and
pixel counter.
[POWER]
OFF/ON
Access code
mode
[8]+[START]
+[POWER]
Registers / deletes the access code.
[POWER]
OFF/ON
Function set-
ting mode
[1]+[*]+
[POWER]
Sets the function table.
[POWER]
OFF/ON
Test mode
[1]+[3]+
[POWER]
Checks the operation of the equipment.
[POWER]
OFF/ON
Warming up
Output check
mode
Input check
mode
Adjustment
mode
Setting
mode
List print
mode
Access code
mode
Function
setting mode
[POWER]
ON
Normal
Ready
[POWER]
OFF
To user
*1
[0][3]
[0][4]
Test print
mode
[0][7]
[0][5]
[0][8]
[1][*]
[9][START]
[8][START]
State transition diagram of self-diagnosis modes
07/11
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 12: ......
Page 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Page 236: ......
Page 237: ......