© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
PREVENTIVE MAINTENANCE (PM)
4 - 5
4
F. Main charger
G. Transfer / Separation charger
H. Drum/Cleaner related section
Items to check
Cleaning Lubrication
Replacement
(KD)
Operation
check
Parts list
<P-I>
Remarks
F1
Main charger case
B
P18-I1
*f1
F2
Needle electrode
72/90
P18-I2
*f1
F3
Contact point of termi-
nals
B
F4
Main charger wire
cleaner
R
P18-I7
F5
Main charger grid
72/90
P18-I3
Items to check
Cleaning Lubrication
Replacement
(KD)
Operation
check
Parts list
<P-I>
Remarks
G1
Charger case
B
P19-I2
*g1
G2
Transfer charger wire
72/90
P19-I18
*g1
G3
Separation charger
wire
72/90
P19-I18
*g1
G4
Pre-transfer guide
B or A
G5
Post-transfer guide
B or A
G6
Separation supporter
B
P19-I17
G7
Terminal cover
B
P19-I10
G8
Contact point of termi-
nals
B
G9
Transfer guide roller
B
R
P19-I14
Items to check
Cleaning Lubrication
Replacement
(KD)
Operation
check
Parts list
<P-I>
Remarks
H1
Photoconductive drum
72/90
Chap.
4.7.2
H2
Discharge LED
B
H3
Whole cleaner unit
B
H4
Drum cleaning blade
72/90
P20-I5
*h1
H5
Separation finger for
drum
72/90
P20-I17
*h2
H6
Recovery blade
B
72/90
P20-I6
*h3
H7
Ozone filter
72/90
P11-I3
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 12: ......
Page 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Page 236: ......
Page 237: ......