© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ADJUSTMENT
3 - 27
3
3.5
Image Quality Adjustment (Scanning Function)
3.5.1
Density adjustment
Adjusts the center density and the variation of density adjustment button.
< Adjustment Mode (05) >
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(4) Press the [INTERRUPT] button to store the value. The equipment goes back to the ready state.
(5) Turn the power OFF and then back ON to perform scanning job.
(6) If the desired image density has not been attained, repeat step (2) to (5).
Original mode
Item to be adjusted
Remarks
Text/Photo
Photo
Text
845
847
846
Manual density mode center
value
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
850
852
851
Manual density mode light
step value
The larger the value is, the lighter the
light side becomes.
Acceptable values: 0 to 255
855
857
856
Manual density mode dark
step value
The larger the value is, the darker the
dark side becomes.
Acceptable values: 0 to 255
860
862
861
Automatic density mode
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
06/04