© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 43
2
414
Devel-
oper
Toner density life correc-
tion switching
ALL
0
<0-7>
M
0: Unchanged (Default)
1: Approx. 0.1 wt%
lower
2: Approx. 0.2 wt%
higher
3: Approx. 0.5 wt%
higher
4: Approx. 0.6 wt%
lower
5: Approx. 0.8 wt%
lower
6: Approx. 1.0 wt%
lower
7: Approx. 1.3 wt%
lower
1
424-0
Fuser
Temperature
drop switching
time setting in
ready status
(Center ther-
mistor)
The first
drop
ALL
15
<2-60>
M
This code is valid only
when “20” is set to 08-
886.
Setting value x 1 min.:
from 2 to 60 min. later
4
424-1
The sec-
ond drop
ALL
15
<2-60>
M
4
424-2
The third
drop
ALL
15
<2-60>
M
4
424-3
The fourth
drop
ALL
15
<2-60>
M
4
425-0
Fuser
Temperature
drop switching
time setting in
ready status
(Side ther-
mistor)
The first
drop
ALL
15
<2-60>
M
4
425-1
The sec-
ond drop
ALL
15
<2-60>
M
4
425-2
The third
drop
ALL
15
<2-60>
M
4
425-3
The fourth
drop
ALL
15
<2-60>
M
4
433-0
Fuser
Temperature
control lower
limit
(Plain paper/
at ordinary
temperature)
Center
thermistor
ALL
5
<0-12>
M
0: 130°C 1: 135°C
2: 140°C 3: 145°C
4: 150°C 5: 155°C
6: 160°C 7: 165°C
8: 170°C 9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
433-1
Side ther-
mistor
ALL
3
<0-12>
M
4
437
Fuser
Fuser roller temperature
during printing
(Center thermistor /Thick
paper 2)
ALL
9
<0-14>
M
0: 140°C 1: 145°C
2: 150°C 3: 155°C
4: 160°C 5: 165°C
6: 170°C 7: 175°C
8: 180°C 9: 185°C
10: 190°C
11: 195°C
12: 200°C
13: 205°C
14: 210°C
1
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM