e-STUDIO163/166/203/206
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 52
800-0
Fuser
Temperature
control lower
limit
(OHP film)
Center
thermistor
ALL
7
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
800-1
Side ther-
mistor
ALL
5
<0-12>
M
4
801-0
Fuser
Temperature
control lower
limit
(Thick paper
1)
Center
thermistor
ALL
7
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
801-1
Side ther-
mistor
ALL
5
<0-12>
M
4
802-0
Fuser
Temperature
control lower
limit
(Thick paper
2)
Center
thermistor
ALL
11
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
802-1
Side ther-
mistor
ALL
11
<0-12>
M
4
804-0
Fuser
Temperature
control lower
limit
(Envelope)
Center
thermistor
ALL
11
<0-12>
M
0: 130°C
1: 135°C
2: 140°C
3: 145°C
4: 150°C
5: 155°C
6: 160°C
7: 165°C
8: 170°C
9: 175°C
10: 180°C
11: 185°C
12: 120°C
4
804-1
Side ther-
mistor
ALL
11
<0-12>
M
4
Setting mode (08)
Code
Classifi-
cation
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 12: ......
Page 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Page 236: ......
Page 237: ......