© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 21
2
Notes:
• The digit after the hyphen in “Code” of the following table is a sub code.
• In “RAM”, the SRAM of the board in which the data of each code is stored is indicated. “M”
and “SYS” stands for the MAIN board.
Adjustment mode (05)
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
200
Devel-
oper
Automatic adjustment of
auto-toner sensor
(Fuser heater ON)
ALL
-
-
As the value increases,
the sensor output
increases correspond-
ingly.
The value starts chang-
ing approx. 2 minutes
after this adjustment was
started and is automati-
cally set in the range of
2.35 to 2.45 V.
*
Selection is disable
when developer unit
is not installed.
(Chap. 3.1)
17
201
Devel-
oper
Correction of auto-toner
sensor
(Fuser heater ON)
ALL
141
<0-255>
M
Corrects the control
value of the auto-toner
sensor setup in 05-200.
*
Selection is disable
when developer unit
is not installed.
3
205
Devel-
oper
Developer bias DC output
adjustment
ALL
135
<0-255>
M
As the value increases,
the transformer output
increases correspond-
ingly. Remove the devel-
oper unit and install the
adjustment jig to make
adjustment.
(Chap. 3.6)
3
210
Charger Main charger grid bias out-
put adjustment
ALL
75
<0-255>
M
3
220
Transfer Transfer transformer DC
output adjustment (H)
ALL
117
<0-255>
M
3
221
Transfer Transfer transformer DC
output adjustment (C)
ALL
128
<0-255>
M
3
222
Transfer Transfer transformer DC
output adjustment (L)
ALL
101
<0-255>
M
3
233
Separa-
tion
Separation transformer DC
output adjustment (H)
ALL
65
<0-255>
M
3
234
Separa-
tion
Separation transformer DC
output adjustment (C)
ALL
65
<0-255>
M
3
235
Separa-
tion
Separation transformer DC
output adjustment (L)
ALL
47
<0-255>
M
3
247
Devel-
oper
Relative humidity latest
value
ALL
50
<0-100>
M
Displaying of the relative
humidity latest value.
2
248
Devel-
oper
Drum temperature latest
value
ALL
25
<0-100>
M
Displaying of the drum
temperature latest value.
2
270
Devel-
oper
Temperature latest value
ALL
25
<0-50>
M
Displaying of the temper-
ature latest value.
2
280
Process Forced performing of idling
for toner recycle
ALL
-
M
Perfom this adjustment
before the replacement
of the developer mate-
rial.(The toner is forcibly
removed from the
cleaner.)
6
286
Laser
Laser power adjustment
ALL
60
<0-255>
M
When the value
increases, the laser out-
put increases corre-
spondingly.
3
07/02
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 12: ......
Page 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Page 236: ......
Page 237: ......