e-STUDIO163/166/203/206
© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND SELF-DIAGNOSTIC MODE
2 - 22
305
Scanner Image location adjustment
of secondary scanning
direction
(scanner section)
ALL
120
<51-206>
SYS When the value
increases by “1”, the
image shifts by approx.
0.0640 mm toward the
trailing edge of the
paper.
During this adjustment,
the density LED blinks.
1
306
Scanner Image location adjustment
of primary scanning direc-
tion
(scanner section)
ALL
130
<121-
136>
SYS When the value
increases by “1”, the
image shifts by approx.
0.169 mm toward the
front side of the paper.
During this adjustment,
the density LED blinks.
1
310
Scanner Forced performing of peak
detection
ALL
-
-
Activates the light inten-
sity adjustment control
During this adjustment,
the density LED blinks.
7
311
Scanner LED (R) current effective
value setting
ALL
76
<0-255>
SYS Displays total of the ini-
tial value and light inten-
sity correction value.
1
312
Scanner LED (B) current effective
value setting
ALL
62
<0-255>
SYS Displays total of the ini-
tial value and light inten-
sity correction value.
1
313
Scanner LED (YG) current effective
value setting
ALL
160
<0-255>
SYS Displays total of the ini-
tial value and light inten-
sity correction value.
1
340
Scanner Reproduction ratio adjust-
ment of secondary scan-
ning direction
(scanner section)
ALL
125
<76-181>
SYS When the value
increases by “1”, the
reproduction ratio in the
secondary scanning
direction (vertical to
paper feeding direction)
increases by approx.
0.0947%.
During this adjustment,
the density LED blinks.
1
350
Scanner Shading posi-
tion adjust-
ment
Original
glass
ALL
128
<118-
138>
SYS 0.064 mm/step
During this adjustment,
the density LED blinks.
1
351
ADF
ALL
128
<118-
138>
SYS
1
354
ADF
Adjustment of ADF paper
alignment
ALL
10
<0-20>
SYS When the value
increases by “1”, the
aligning amount
increases by approx.
0.4 mm.
1
357
ADF
Fine adjustment of ADF
transport speed
ALL
50
<0-100>
SYS When the value
increases by “1”, the
reproduction ratio of the
secondary scanning
direction when using the
ADF increases by
approx. 0.1%.
During this adjustment,
the density LED blinks.
1
Adjustment mode (05)
Code
Classi-
fication
Items
Func-
tion
Default
<Accept-
able
value>
RAM
Contents
Proce-
dure
09/01
Summary of Contents for e-STUDIO163
Page 6: ......
Page 10: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved CONTENTS 4 ...
Page 12: ......
Page 142: ...e STUDIO163 166 203 206 2005 2009 TOSHIBA TEC CORPORATION All rights reserved ADJUSTMENT 3 58 ...
Page 236: ......
Page 237: ......