ADJUSTMENT
3 - 10
Fig. 3-7 Grid pattern
<Procedure>
[0] [5] [Power ON] [1] [INTERRUPT] [Drawer number] [START]
A:
05-401 (Drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
B:
05-411 (Drawer, A3/LD)
52±0.5 mm (0.05 mm/step)
Key in the same value for 05-410.
C:
05-421 (Drawer, A3/LD)
200±0.5 mm (0.125 mm/step)
D: 05-440 (Drawer, A3/LD), 441 (PFU, A4/LT), 442 (Bypass feed, A4/LT)
50±0.5 mm(0.4 mm/step)
A
21
6
1
B
D
6
30
2
C
10
Feeding direction