© 2005 - 2009 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO163/166/203/206
ADJUSTMENT
3 - 57
3
3.10.7
Adjustment of ADF Opening/Closing Sensor
Adjust the bracket position so that the sensor is turned ON when the height “A” becomes 100 mm or
less (within the empty weight falling limit).
Fig. 3-62
Fig. 3-63
A
Summary of Contents for e-STUDIO163