Machine Faults (continued)
Fault ID
Fault Title
Fault Description
Controller
Action
Recommended Service Actions
C14C4
PTO Output
-Overcurrent
Overcurrent detected on
PTO output. Indicates
short to ground.
1.
Check the PTO output circuit wiring and all
of the output circuit connectors
2.
Test the PTO output circuit wiring
3.
Test the hydraulic solenoid valve EH coil
4.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C14C5
PTO Output -
Open Circuit
Open Circuit detected
on PTO output.
1.
Check the PTO output circuit wiring and all
of the output circuit connectors
2.
Test the PTO output circuit wiring
3.
Test the hydraulic solenoid valve EH coil
4.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C1514
Front
Hydraulic
Pressure
Sensor - Short
to Ground
Front hydraulic pressure
sensor is shorted to
ground (out of range
low)
PTO is disabled
and machine
enters limp mode
after the machine
comes to a stop
1.
Check front pressure sensor (left side of
traction pump) wiring and connector
2.
Test the pressure sensor wiring
3.
Test the pressure sensor if possible and
replace if necessary
C1515
Front
Hydraulic
Pressure
Sensor - Open
Circuit
Front hydraulic pressure
sensor is open (out of
range high)
PTO is disabled
and machine
enters limp mode
after the machine
comes to a stop
1.
Check front pressure sensor (left side of
traction pump) wiring and connector
2.
Test the pressure sensor wiring
3.
Test the pressure sensor if possible and
replace if necessary
C1524
Rear Hydraulic
Pressure
Sensor - Short
to Ground
Rear hydraulic pressure
sensor is shorted to
ground (out of range
low)
PTO is disabled
and machine
enters limp mode
after the machine
comes to a stop
1.
Check rear pressure sensor (right side of
traction pump) wiring and connector
2.
Test the pressure sensor wiring
3.
Test the pressure sensor if possible and
replace if necessary
C1525
Rear Hydraulic
Pressure
Sensor - Open
Circuit
Rear hydraulic pressure
sensor is open (out of
range high)
PTO is disabled
and machine
enters limp mode
after the machine
comes to a stop
1.
Check rear pressure sensor (right side of
traction pump) wiring and connector
2.
Test the pressure sensor wiring
3.
Test the pressure sensor if possible and
replace if necessary
C153C
3-Point Hitch
Raise Stall
3-point hitch raise
output is enabled, but
3-point hitch position
sensor does not report
movement
Raise is
disabled for
paddle-controlled
attachments
1.
If 3-point hitch is moving:
A.
Make sure 3-point hitch position sensor
is properly installed (mounting bracket
is stationary and sensor shaft moves
with lift arm pivot shaft)
B.
Test the 3-point hitch position sensor
2.
If 3-point hitch is not moving:
A.
Make sure the hitch assembly is not
obstructed or over loaded
B.
Service hydraulic cartridge valve SP1
and replace if necessary
C.
Test hydraulic relief valve RV2 and
adjust, service, or replace if necessary
Outcross 9060
Page 3–19
Troubleshooting: Attachment/Loader Problems
18234SL Rev B
Summary of Contents for 07511AA
Page 4: ...Reader Comments Page 4 Outcross 9060 18234SL Rev B ...
Page 18: ...Safety Safety and Instructional Decals Page 1 10 Outcross 9060 18234SL Rev B ...
Page 38: ...Specifications and Maintenance Special Tools Page 2 20 Outcross 9060 18234SL Rev B ...
Page 96: ...Engine Service and Repairs Page 4 24 Outcross 9060 18234SL Rev B ...
Page 208: ...Hydraulic System Service and Repairs Page 5 112 Outcross 9060 18234SL Rev B ...
Page 294: ...Electrical System Service and Repairs Page 6 86 Outcross 9060 18234SL Rev B ...
Page 384: ......