PTO System Problems
Problem
Possible Cause
Corrective Action
An electrical problem exists in the
proportional solenoid valve (EH) circuit.
Test and replace the valve solenoid if
necessary.
Test the machine wire harness
proportional solenoid valve (EH) circuit.
Proportional solenoid valve (EH) in the
main manifold is stuck, leaking or faulty.
Clean the solenoid valve and replace
the seals.
The PTO shaft will not engage.
Replace the solenoid valve if necessary.
Outcross 9060
Page 3–31
Troubleshooting: PTO System Problems
18234SL Rev B