Testing the Decelerator Pedal Neutral Switch (continued)
3. Check the continuity of the switch by connecting a multimeter (ohms setting)
across the connector terminals.
4. When the switch plunger is depressed (decelerator pedal at rest) there
should be continuity (zero ohms resistance) between the switch terminals.
5. When the switch plunger is extended (decelerator pedal depressed) there
should be no continuity (infinite ohms resistance) between the switch
terminals.
6. Replace the switch if necessary.