Attachment/Loader Circuit Testing – Relief Valve Pressure Test
(continued)
g263149
Figure 30
1.
rear attachment upper quick-disconnect (A or retract port)
3. Remove the cap and connect a
34,500 kPa (5000 PSI)
pressure gauge to
the rear attachment upper quick-disconnect (A or retract port) at the rear
of the machine.
4. Start engine and increase engine speed to (
2300 RPM
).
5. Shift the auxiliary load valve into the A position (rearward).
6. The pressure gauge reading should be
20,684 to 24,131 kPa (3000 to 3500
PSI)
.
7. Release the joystick, stop the engine and record the test results.
8. If circuit relief pressure reading is incorrect, clean, repair or replace the
auxiliary load valve relief valve; refer to
Auxiliary Load Valve Service (page
.
9. After testing, remove the pressure gauge and install the supply line cap.