Machine Faults (continued)
Fault ID
Fault Title
Fault Description
Controller
Action
Recommended Service Actions
P0617
Engine Start
Output - Short
to Battery
Low current detected
on engine start output
. Indicates a short to
battery
1.
Check the engine start output circuit wiring
and all of the output circuit connectors
2.
Test the engine start output circuit wiring
between T1: TEC and Engine ECU
3.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
P06E9
Starter
Time-out
Starter has been
engaged continuously
for more than 30
seconds
Starter output is
disabled
1.
Check key switch is not stuck in start
position
2.
Test key switch and replace if necessary
3.
Test start relay and replace if necessary
P0939
Hydraulic Fluid
Temperature
Sender - Short
to Ground
Short to ground
detected on hydraulic
temperature sender
1.
Check temperature sender wiring and
connector
2.
Test temperature sender and replace if
necessary
P0940
Hydraulic Fluid
Temperature
Sender - Open
Circuit
Open circuit detected on
hydraulic temperature
sender
1.
Check temperature sender wiring and
connector
2.
Test temperature sender and replace if
necessary
P100C
Engine
Coolant
Temperature
Above
Threshold -
PTO Disabled
Engine coolant
temperature has
exceeded 105° C (221°
F)
PTO is disabled
1.
Allow engine to cool
2.
Check fan condition and operation
3.
Clear air flow passages
4.
Check coolant level and condition, adjust
and replace as necessary
5.
Check temperature sender wiring and
connector
6.
Test temperature sender and replace if
necessary
P100D
Engine
Coolant
Temperature
Above
Threshold -
Engine Shut
Down
Engine coolant
temperature has
exceeded 115° C (239°
F)
Engine is shut
down
1.
Allow engine to cool
2.
Check fan condition and operation
3.
Clear air flow passages
4.
Check coolant level and condition, adjust
and replace as necessary
5.
Check temperature sender wiring and
connector
6.
Test temperature sender and replace if
necessary
P1104
Traction
Coil (front
pump forward
valve - C1)
Overcurrent
Overcurrent detected.
Indicates a short to
ground.
1.
Use the InfoCenter to verify the traction coil
operation (TRACTION OUTPUTS–FRONT
FWD HYDRO)
2.
If no amperage reading is displayed:
A.
Check the traction coil wiring and
connector
B.
Test the traction coil wiring
3.
Test the traction coil and replace if necessary
4.
Replace T1: TEC (contact your Authorized
Toro Distributor for assistance)
Troubleshooting: Attachment/Loader Problems
Page 3–8
Outcross 9060
18234SL Rev B
Summary of Contents for 07511AA
Page 4: ...Reader Comments Page 4 Outcross 9060 18234SL Rev B ...
Page 18: ...Safety Safety and Instructional Decals Page 1 10 Outcross 9060 18234SL Rev B ...
Page 38: ...Specifications and Maintenance Special Tools Page 2 20 Outcross 9060 18234SL Rev B ...
Page 96: ...Engine Service and Repairs Page 4 24 Outcross 9060 18234SL Rev B ...
Page 208: ...Hydraulic System Service and Repairs Page 5 112 Outcross 9060 18234SL Rev B ...
Page 294: ...Electrical System Service and Repairs Page 6 86 Outcross 9060 18234SL Rev B ...
Page 384: ......