Machine Faults (continued)
Fault ID
Fault Title
Fault Description
Controller
Action
Recommended Service Actions
C14A4
Optional
Solenoid
Control Valve
(SCV) Output -
Overcurrent
Overcurrent detected
on optional SCV output.
Indicates short to
ground.
1.
Check the optional SCV output circuit wiring
and all of the output circuit connectors
2.
Test the optional SCV output circuit wiring
3.
Test the SCV relay
4.
Test all 4 of the hydraulic solenoid valve
SCV coils
5.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C14A5
Optional
Solenoid
Control Valve
(SCV) Output -
Open Circuit
Open Circuit detected
on optional SCV output.
1.
Check the optional SCV output circuit wiring
and all of the output circuit connectors
2.
Test the optional SCV output circuit wiring
3.
Test the SCV relay
4.
Test all 4 of the hydraulic solenoid valve
SCV coils
5.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C14B0
Range Hi
Output - Fault
Undetermined
The fault type is
undetermined due
to hardware restrictions.
Cycling the output will
allow the software to
determine whether the
fault is because of a
short to battery, short
to ground, or an open
circuit.
Cycle the mode selector to LOW and back to
HIGH (key switch in RUN position) to allow the
software to determine the fault type
C14B3
Range Hi
Output - Short
to Battery
Low current detected
on range Hi output.
Indicates a short to
battery
1.
Check the range Hi output circuit wiring and
all of the output circuit connectors
2.
Test the range Hi output circuit wiring
3.
Test the hydraulic solenoid valve SV1 coil
4.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C14B4
Range Hi
Output -
Overcurrent
Overcurrent detected
on range Hi output.
Indicates short to
ground.
1.
Check the range Hi output circuit wiring and
all of the output circuit connectors
2.
Test the range Hi output circuit wiring
3.
Test the hydraulic solenoid valve SV1 coil
4.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
C14B5
Range Hi
Output - Open
Circuit
Open circuit detected
on range Hi output.
1.
Check the range Hi output circuit wiring and
all of the output circuit connectors
2.
Test the range Hi output circuit wiring
3.
Test the hydraulic solenoid valve SV1 coil
4.
Replace the T1: TEC (contact your
Authorized Toro Distributor for assistance)
Troubleshooting: Attachment/Loader Problems
Page 3–18
Outcross 9060
18234SL Rev B
Summary of Contents for 07511AA
Page 4: ...Reader Comments Page 4 Outcross 9060 18234SL Rev B ...
Page 18: ...Safety Safety and Instructional Decals Page 1 10 Outcross 9060 18234SL Rev B ...
Page 38: ...Specifications and Maintenance Special Tools Page 2 20 Outcross 9060 18234SL Rev B ...
Page 96: ...Engine Service and Repairs Page 4 24 Outcross 9060 18234SL Rev B ...
Page 208: ...Hydraulic System Service and Repairs Page 5 112 Outcross 9060 18234SL Rev B ...
Page 294: ...Electrical System Service and Repairs Page 6 86 Outcross 9060 18234SL Rev B ...
Page 384: ......