Injection Molding Machine Chapter 4
V3.0
4-39
2.20 Automatic mold adjustment
On CLAMP or EJECTION screen press F3 MOLD ADJ.
,
or use the direction key in the main
menu screen to move the cursor to MOULD ADJ. To display this screen.
V1: 0/ 0
0/ 0
V2:
0/ 0
P1: 0/ 0
P2:
100.0mm
50.0mm
110.0mm
1.0mm
ACTION STATUS
M:
03D05M07Y
10h25m10s
20°C
3W
F2
F1
F3
F4
F5
F6
F7
F8
TONNAGE
MENU
01
100.0 mm
100.0 mm
ORIGINAL DIE HEIGHT
DIE HEIGHT JOG
DIE HEIGHT ADJ.
DIE HEIGHT ADJ. PRESS
PRESET DIE HEIGHT
120 TON
CLAMPING FORCE
ORIGINAL CLAMPING FORCE
DIE HEIGHT ADJ. SPEED
PRESET CLAMPING FORCE
120 TON
120 TON
50 bar
OFF
OFF
:
:
:
:
:
:
:
:
:
AUTO
AUTO
NOTE
CHECK LUB. CONDITION IS WELL AT DIE HEIGHT MECHANISM.
DO AUTO DIE HEIGHT WITHOUT MOLD FIT ON.
1.
2.
CHANGE
LOG
ALARM
LOG
I
A
B
E
C
G
D
F
H
J
OFF
MOLD SETUP MODE
:
DO AUTO TONNAGE AFTER AUTO DIE HEIGHT AND MOLD FIT ON.
3.
MOLD
SUPPORT
DIE HEIGH
8%
Screen 4-24
A
DIE HEIGHT ADJ.:
Before adjust die height
,
die height adjustment function has to be turn
ON.
B
DIE HEIGHT ADJ. PRESS:
Die height adjusting pressure shall not be set higher than
50bar.
C
DIE HEIGHT ADJ. SPEED:
Die height adjusting speed shall not be set higher than10%.
D
Make sure that there is no mold on the machine.
E
PRESET DIE HEIGHT:
Measure mold thickness with ruler and key in to preset mold
thickness
,
close safety door.
F
AUTO DIE HEIGH:
Press function key F3
,
automatic die height adjustment process start
,
at this time
,
original die height value will change as gear rotating until it is equal that
preset die height setting
,
then machine will give an alarm signaling completion of die
height adjustment.
Upon completion of the above operation
,
open the safety gate and load the mould in and
secure it.
G
PRESET CLAMPING FORCE:
After fitted mold
,
key in the present clamping force
,
close
Summary of Contents for TMC 1000E
Page 20: ...Injection Molding Machine Chapter 2 2 4 V3 0 2 Machine dimensions ...
Page 21: ...Injection Molding Machine Chapter 2 2 5 V3 0 3 Operating position ...
Page 22: ...Injection Molding Machine Chapter 2 2 6 V3 0 4 Safety devices layouts ...
Page 23: ...Injection Molding Machine Chapter 2 2 7 V3 0 5 Position of signs and labels ...
Page 75: ...Injection Molding Machine Chapter 4 V3 0 4 32 starts running to cool down barrel ...
Page 132: ...Injection Molding Machine Chapter 6 V3 0 6 11 4 3 Lubrication points and timing ...
Page 136: ...Injection Molding Machine Chapter 6 V3 0 6 15 32 061 120 3141 Nozzle head S45C PCS 1 ...
Page 149: ...Injection Molding Machine Appendix A A 4 V3 0 1 4 INJECTION INJECTION ...
Page 150: ...Injection Molding Machine Appendix A A 5 V3 0 ...
Page 151: ...Injection Molding Machine Appendix A A 6 V3 0 1 5 CHARGING ...
Page 152: ...Injection Molding Machine Appendix A A 7 V3 0 If CARRIAGE MOVEMENT ON then CARRIAGE RETRACT ...
Page 153: ...Injection Molding Machine Appendix A A 8 V3 0 1 6 CLAMP OPENING ...
Page 159: ...Injection Molding Machine Appendix A A 14 V3 0 1 9 2 GAS VENT SEQUENCE ...
Page 160: ...Injection Molding Machine Appendix A A 15 V3 0 1 9 3 INJECTION COMPRESSION SEQUENCE ...
Page 161: ...Injection Molding Machine Appendix A A 16 V3 0 1 9 4 GAS VENT INJECTION COMPRESSION ...