Injection Molding Machine Chapter 4
V3.0
4-14
Ejector forward will be counted one time and ejector backward will also be counted one
time. If count 2 is odd number, ejector will stay at forward position, and it will retract
automatically before next mold close action.
If EJECT ON FLY function is on
,
ejector counter 1 IS NOT used
,
use ejector counter 2
ONLY.
E
DELAY
:
The delay time for ejector advance and retract
,
it is to be used when machine
runs with robot
,
delay some time to let robot move into mold area to catch parts.
Forward delay time is only used for one time
,
while backward delay is used in every
backward movement.
F
EJECT RET. MID. PT.
:
It is the retracted position for ejector forward 2 sequences. ejector
advances to forward position 2
,
then ejector retracts to EJECT RET. MID. PT.
,
3 ejector
advances to the FWD. END
,
4 ejector retracts to RET. END.
G
ROBOT CYCLE TIME.
:
Total cycle time of robot sequences
,
timer start count when
IO.196 is on (enable robot move in mold area)
,
timer stops when IO.222 is on (enable
mold close).
BILL 2011/04/25
Summary of Contents for TMC 1000E
Page 20: ...Injection Molding Machine Chapter 2 2 4 V3 0 2 Machine dimensions ...
Page 21: ...Injection Molding Machine Chapter 2 2 5 V3 0 3 Operating position ...
Page 22: ...Injection Molding Machine Chapter 2 2 6 V3 0 4 Safety devices layouts ...
Page 23: ...Injection Molding Machine Chapter 2 2 7 V3 0 5 Position of signs and labels ...
Page 75: ...Injection Molding Machine Chapter 4 V3 0 4 32 starts running to cool down barrel ...
Page 132: ...Injection Molding Machine Chapter 6 V3 0 6 11 4 3 Lubrication points and timing ...
Page 136: ...Injection Molding Machine Chapter 6 V3 0 6 15 32 061 120 3141 Nozzle head S45C PCS 1 ...
Page 149: ...Injection Molding Machine Appendix A A 4 V3 0 1 4 INJECTION INJECTION ...
Page 150: ...Injection Molding Machine Appendix A A 5 V3 0 ...
Page 151: ...Injection Molding Machine Appendix A A 6 V3 0 1 5 CHARGING ...
Page 152: ...Injection Molding Machine Appendix A A 7 V3 0 If CARRIAGE MOVEMENT ON then CARRIAGE RETRACT ...
Page 153: ...Injection Molding Machine Appendix A A 8 V3 0 1 6 CLAMP OPENING ...
Page 159: ...Injection Molding Machine Appendix A A 14 V3 0 1 9 2 GAS VENT SEQUENCE ...
Page 160: ...Injection Molding Machine Appendix A A 15 V3 0 1 9 3 INJECTION COMPRESSION SEQUENCE ...
Page 161: ...Injection Molding Machine Appendix A A 16 V3 0 1 9 4 GAS VENT INJECTION COMPRESSION ...