Injection Molding Machine Chapter 5
V3.0
5-5
Item Possible
Causes
Solution
1.10
No mold thickness adju
stment
A Mold is not unloaded from
machine
B Mold adjusting gear locking screw
is not loosened.
C Mold adjusting brake is not
released
D Mold height limit switch OFF
E Poor lubrication on die adjusting
device or tie bar.
F Poor sensing of proximity switch
G
Improper setting of preset die
height available.
H Improper setting of pressure and
speed
I Foreign objects are existed
between gear set.
J Supporting bracket and strut for
the gear are loose
K Directional valve stuck
L
Directional valve signal wire
failure
A Unload mold first
B Release locking screw
C Check mold adjusting braking device
D Check and repair LS28
,
LS29
E Add grease for lubrication
F Check distance/circuit of proximity switch
G Correct settings
H Correct settings
I Clear
foreign
matters
J Tighten up
K Clean V28
,
V29 manually press spool
L Check and repair signal wires 178/0
,
179/0
1.11
Automatic cl
amping force fails
A Clamp close monitor time too short
B Error in die height available and
actual mold size exceeding 5mm
C Thermal expansion of mold and
improper high pressure mold
locking position.
D mold is dirty
A Increase clamp close monitor time
B Correct parameter
C Increase high pressure mold locking position
D Clean mold
Summary of Contents for TMC 1000E
Page 20: ...Injection Molding Machine Chapter 2 2 4 V3 0 2 Machine dimensions ...
Page 21: ...Injection Molding Machine Chapter 2 2 5 V3 0 3 Operating position ...
Page 22: ...Injection Molding Machine Chapter 2 2 6 V3 0 4 Safety devices layouts ...
Page 23: ...Injection Molding Machine Chapter 2 2 7 V3 0 5 Position of signs and labels ...
Page 75: ...Injection Molding Machine Chapter 4 V3 0 4 32 starts running to cool down barrel ...
Page 132: ...Injection Molding Machine Chapter 6 V3 0 6 11 4 3 Lubrication points and timing ...
Page 136: ...Injection Molding Machine Chapter 6 V3 0 6 15 32 061 120 3141 Nozzle head S45C PCS 1 ...
Page 149: ...Injection Molding Machine Appendix A A 4 V3 0 1 4 INJECTION INJECTION ...
Page 150: ...Injection Molding Machine Appendix A A 5 V3 0 ...
Page 151: ...Injection Molding Machine Appendix A A 6 V3 0 1 5 CHARGING ...
Page 152: ...Injection Molding Machine Appendix A A 7 V3 0 If CARRIAGE MOVEMENT ON then CARRIAGE RETRACT ...
Page 153: ...Injection Molding Machine Appendix A A 8 V3 0 1 6 CLAMP OPENING ...
Page 159: ...Injection Molding Machine Appendix A A 14 V3 0 1 9 2 GAS VENT SEQUENCE ...
Page 160: ...Injection Molding Machine Appendix A A 15 V3 0 1 9 3 INJECTION COMPRESSION SEQUENCE ...
Page 161: ...Injection Molding Machine Appendix A A 16 V3 0 1 9 4 GAS VENT INJECTION COMPRESSION ...