124
Sanhua compressor drive testing methods (Step 13)
Adjust the multimeter to diode gear, and black probe to measure
DC+ and red probe to measure W, with reading value as below
(10% error is allowable)
①
Loose connection of compressor:
Normally, on a 3 phase compressor the resistance among phases should be less than 1
Ω
.
If resistance reaches K
Ω
or M
Ω
, it indicates that the winding is damaged; the resistance