Possible causes:
①
Inverter 2 compressor-top temperature probe fails
②
Inverter 2 compressor-top temperature probe socket at main board gets loose
③
Inverter 2 compressor-top temperature detection port at the main board is damaged
2.20 Fan drive communication fault
Code displayed:
ODU main board displays E005/E029 (applicable to AA/AS/AX models).
Fault detection method:
Check fault codes displayed on master control board of ODU.
Fault identification conditions:
Master control board of ODU displays fault code
E005/E029.
Possible causes:
①
Drive is incorrectly set
②
Incorrect address DIP switch
③
Incorrect communication line connection