TI120 Series Variable Frequency Drive
Parameter List
- 36 -
Parameter
Name
Setting range
Factory
default
Register address
Properties
P10.03
X4 terminal
function
selection
17
0x1003
●
P10.04
X5 terminal
function
selection
18
0x1004
●
P10.05
X6 terminal
function
selection
0
0x1005
●
P10.06
X7/HDI
terminal
function
selection
0
0x1006
●
P10.08
AI·1 terminal
function
selection
0
0x1008
●
P10.09
AI2 terminal
function
selection
0
0x1009
●
P10.11
Terminal
control
operation
mode
selection
0: 2-wire operation mode 1
1: 2-wire operation mode 2
2: 3-wire operation mode 1
3: 3-wire operation mode 2
0
0x100B
●
P10.12
Logic state
setting of
input terminal
Ones: Bit0
~
Bit3:X1~X4
Tens: Bit4
~
Bit6:X5~X7
Hundreds: Bit8
~
Bit9:AI1~AI2
0: positive logic
1: negative logic
000
0x100C
●
P10.13
Input terminal
filtering time
0.000s~2.000s
0.010s
0x100D
○
P10.14
X1 terminal
conduction
delay
0.0s~3600.0s
0.0s
0x100E
○