TI120 Series Variable Frequency Drive
Parameter List
- 31 -
Parameter
Name
Setting range
Factory
default
Register address
Properties
P03.04
Speed loop
low speed
integration
time
0.001~5.000s
0.200s
0x0304
○
P03.05
Speed loop PI
switching
frequency 1
0.00Hz~P03.06
5.00Hz
0x0305
○
P03.06
Speed loop PI
switching
frequency 2
P03.05~upper limit
frequency
10.00Hz
0x0306
○
P03.07
Speed
feedback
filtering time
0.0ms~1000.0ms
15.0ms
0x0307
○
P03.08
Drive torque
selection
channel
Ones: torque control
selection channel
Tens: speed control
selection channel
0: digital setting P03.09
1: analog input AI1
2: analog input AI2
3: reserve
4: Min[AI1,AI2]
5: Max[AI1,AI2]
6: Sub[AI1,AI2]
7: Add[AI1,AI2]
8: pulse given HDI
9: maximum value of
variable frequency drive
90
0x0308
●
P03.09
Digital setting
of drive torque
-200.0%~200.0%
150.0%
0x0309
○
P03.10
Generation
torque
selection
channel
Ones: torque control
selection channel
Tens: speed control
selection channel
0: digital setting P03.11
1: analog input AI1
99
0x030A
●