Set Special Commands
These commands are product specific.
Master Sends:
lc a1 a2
8D
nn d1 d2 d3 d4 d5 d6 cs
Slave Returns:
lc a1 a2
8D
nn d1 d2 d3 d4 d5 d6 cs
Byte
Master
Slave
d1
Command byte
d2
Entered Value MSB
d3
Entered Value
d4
Entered Value
d5
Entered Value
d6
Entered Value LSB
Command
Master sends
Description
Slave returns
0x00
CA 00 01 8D 02 d1 d2 cs
Set analog option
CA 00 01 8D 03 00 d2 d3 cs
d1 = command byte = 00
d2 = analog option byte
0x80
CA 00 01 8D 01 80 cs
Request PM status
CA 00 01 8D 03 80 d2 d3 cs
Set analog option command
d2 analog option byte
b.6 - b.7 = unused
b.4 - b.5 = DAC enable
b.2 - b.3 = DAC out
b.0 - b.1 = analog in
0 = voltage
0 = voltage
0 = voltage
1 = millivolt
1 = millivolt
1 = millivolt
2 = current
2 = current
2 = current
3 = no change
3 = no change
3 = no change
Eg. Command to enable DAC, set DAC out to Voltage and set Analog in to millivolt
Master sends
Slave returns
CA 00 01 8D 02 00 11 5E
CA 00 01 8D 02 00 11 5E
Eg. Command to set DAC out to current without changing DAC enable or analog in
Master sends
Slave returns
CA 00 01 8D 02 00 3B 34
CA 00 01 8D 02 00 19 56
Summary of Contents for ThermoFlex10000
Page 2: ......
Page 36: ...ThermoFlex900 5000 Thermo Scientific...
Page 42: ...DI SDS 4 0 gpm 15 1 lpm ThermoFlex900 5000 Thermo Scientific...
Page 79: ...517 2014 16 2014 ThemoFlex24000...
Page 100: ...Section 2 2 20 ThermoFlex Thermo Scientific...
Page 136: ...Section 4 4 14 ThermoFlex Thermo Scientific...
Page 168: ...Section 7 7 14 ThermoFlex Thermo Scientific...
Page 191: ...C 10 ThermoFlex Appendix C Thermo Scientific...
Page 208: ......
Page 209: ......