LLZ 421
Operation and Maintenance
Operation
ILS 420
3−17
Ed. 01.10
SOAC
In the Menu List window the following button definitions are used:
− S1
ENTER
to enter/confirm selected item in the Menu List
− S2
↑
to select menu item, upwards, selected item is pointed with >
− S3
↓
to select menu item, downwards, selected item is pointed with >
− S4
STATUS
to return to the Status window (see Fig. 3−6)
1
4
2
3
1
4
2
3
ILS 420 LLZ ’LLZ−420T’ 110.10MHz
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
TX 1: ON TX 2: ON
STANDBY MAIN
LOAD AERIAL
146 hrs. 145 hrs.
Monitor: −−1−− −−2−−
Executive: NORMAL NORMAL
Farfield: NORMAL NORMAL
Standby: NORMAL NORMAL
RWY: ON
MENU MONITOR ALERTS CONTROL
MENU LIST
−−−−−−−−−−−
> SHOW ALERTS
CONTROL
MONITOR QUICK ACCESS
MONITOR EXEC & FIELD all parameters
MONITOR STANDBY all parameters
POWER SUPPLIES
WAVEFORM DATA / FLIGHT CHECK
POWER AMPLIFIER DATA (CRS and CLR)
MTBO
CONFIGURATION DATA
ENTER
↑
SELECT
↓
STATUS
**
*
* depends on configuration
*
control buttons (S)
* CONTROL and FLIGHT CHECK not for ’REMOTE’
**
Fig. 3−15
MENU select and MENU LIST window (example)
The windows shown after selecting STATUS, SHOW ALERTS, CONTROL and MONITOR QUICK AC-
CESS Menu List items are already described and shown in previous Figs. 3−6 to 3−14.
Following Figs. 3−16 to 3−20 show/describe the Menu List windows after selecting the other items:
In the Monitor Exec. & Field window the following button definitions are used:
− S1
MENU
to return to the Menu List window
− S2
↑
to scroll parameters upwards
− S3
↓
to scroll parameters downwards
− S4
STBY−MON
to go to Monitor Standby window (see Fig. 3−17)
1
4
2
3
1
4
2
3
MENU LIST
−−−−−−−−−−−
SHOW ALERTS
CONTROL
MONITOR QUICK ACCESS
> MONITOR EXEC & FIELD all parameters
MONITOR STANDBY all parameters
POWER SUPPLIES
WAVEFORM DATA / FLIGHT CHECK
POWER AMPLIFIER DATA (CRS and CLR)
MTBO
CONFIGURATION DATA
ENTER
↑
SELECT
↓
STATUS
AERIAL: TX2 / ON AERIAL−ALL
1 MONITOR 2
CRS POS RF % 100.2 100.3
DDM % 0.0 0.0
SDM % 39.0 39.1
IDENT % 8.0 8.0
CRS WDTH RF % 100.9 100.8
DDM % 15.5 15.5
SDM % 38.9 39.0
CLR WDTH RF % 100.0 100.2
DDM % 23.7 23.8
SDM % 39.9 39.9
MENU
↑
SCROLL
↓
STBY−MON
1.
2.
control buttons (S)
Fig. 3−16
MONITOR EXEC. & FIELD select and Monitor Exec. & Field window (example)
Summary of Contents for 421
Page 2: ......
Page 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Page 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Page 56: ......
Page 58: ......
Page 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Page 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Page 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Page 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Page 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Page 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Page 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...