LLZ 421
Operation
Operation and Maintenance
ILS 420
3−2
Ed. 01.07
SOAC
3.2.1
Indicators and Controls on LCP Front
Indicator
Color
Function if indicator lights
Remarks
ALARM
red
Monitor 1 and 2 are in ALARM state (i.e. relevant sig-
nals are out of tolerance):
Alarm is set if the monitors being in executive mode
detect that the signal is radiated with defects caused
by faults in the aerial transmitter (or antenna); the
faulty transmitter is shut down and if available the
standby transmitter is changed to aerial. If the radiated
signal remains faulty the system is shut down
or
ECU fault
or
Monitor 1 and 2 are in Bypass/Maintenance Mode.
executive bypass
WARNING
yellow
The station is supplied by battery
or
has a BITE war-
ning
or
Monitor 1 and 2 are in Bypass/Maintenance Mode.
standby bypass
NORMAL
green
All transmitter and monitor equipment is switched on,
initialized and serviceable for the intended category of
operations (no WARNING and no ALARM).
Control
Position
Function
Remarks
Key−Lock
Switch
Push button
REMOTE
LOCAL
MAINTENANCE
S1,S2,S3,S4
S2+S3 simult.
S1+S4 simult.
Station enabled for remote control,
local control commands at LCP disabled
Station enabled for local operation,
control commands from remote disabled
System set to maintenance mode: ’Monitor
Bypass’ is set, ALARM indication is lit.
Function keys meaning defined per SW menu
Lamp test and audible alarm test if simulta-
neously pressed
Call up of LCP control menu, if simultaneously
pressed during LCP reset or system restart
Station is operable.
Local read out of
values possible
Station is not oper-
able.
Remote read out of
values possible
Station is not oper-
able.
Service activity
Ed. 07.08
Summary of Contents for 421
Page 2: ......
Page 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Page 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Page 56: ......
Page 58: ......
Page 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Page 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Page 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Page 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Page 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Page 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Page 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...