LLZ 421
Operation and Maintenance
Operation
ILS 420
3−15
Ed. 01.10
SOAC
In the Show Alerts window the following button definitions are used:
S1
MENU
to go to Menu List window (see Fig. 3−15)
S2
↑
to select item, upwards
S3
↓
to select item, downwards
S4
STATUS
to return to the Status window (see Fig. 3−6)
1
4
2
3
1
4
2
3
SHOW ALERTS
−−−−−−−−−−−−−−−
All parameters OK ! Mode: remote
MENU
↑
SCROLL
↓
STATUS
ILS 420 LLZ ’LLZ−420T’ 110.10MHz
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
TX 1: ON TX 2: ON
STANDBY MAIN
LOAD AERIAL
WAVEFORM 1 WAVEFORM 1
146 hrs. 145 hrs.
Monitor: −−1−− −−2−−
Executive: NORMAL NORMAL
Farfield: NORMAL NORMAL
Standby: NORMAL NORMAL
RWY: ON
MENU MONITOR ALERTS CONTROL
**
*
* depends on configuration
*
control buttons (S)
* contents of window depends on alarm status (list of possible (pre−)alarms see below
Fig. 3−12
ALERTS select and SHOW ALERTS window (example)
The Show Alerts window presents the following alarms/pre−alarms to the user (if existing):
− ECU Data Communication error
− Internal voltage alert
− ECU fault
− Battery low
− Executive monitor bypass on
− Battery driven off
− Farfield* monitor bypass on
− Battery fuse defect
− Standby monitor bypass on
− Mains OFF
− Executive prealarm
− TX1 5V DC OFF
− Standby prealarm
− TX2 5V DC OFF
− Farfield * prealarm
− BCPS OFF
− Monitor fault
− Intrusion alarm
− Monitor BITE
− Smoke detector alarm
− Transmitter change over
− Obstruction light alarm
− Aerial Transmitter off
− Temperature alarm
− Transmitter operational off
− LGM−1 data communication error
− Standby Transmitter off
− LGM−2 data communication error
− Transmitter fault
− LGA−1 data communication error
− Transmitter BITE
− LGA−2 data communication error
− Remote control communication lost
− Configuration mismatch
− AC 1 failure
− Monitors disagree
− AC 2 failure
− Spare A/D Alert
* Monitor name depends on configuration of ’Field Monitoring’.
The Show Alerts window also indicates the actual operational mode (following ’Mode:’):
− "remote"
Remote mode enabled
− "remote maint."
Remote mode with maintenance activity enabled
− "local"
Local operation enabled
Summary of Contents for 421
Page 2: ......
Page 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Page 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Page 56: ......
Page 58: ......
Page 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Page 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Page 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Page 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Page 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Page 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Page 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...