LLZ 421
Operation
Operation and Maintenance
ILS 420
3−16
Ed. 01.10
SOAC
In the Control window (available and visible in key switch position ’LOCAL’ or ’MAINTENANCE’) the
following button definitions are used:
S1
SWITCH
to switch selected item to on/off or 1/2;
if once used the STATUS field indication in the display shows the new state.
S2
↑
to select item, upwards
S3
↓
to select item, downwards
S4
STATUS
to return to the Status window (see Fig. 3−6)
1
4
2
3
1
4
2
3
CONTROLS STATUS
−−−−−−−−− −−−−−−−−
> TX 1 ON
TX 2 ON
TX ANTENNA 1
MON BYPASS EXE OFF
MON BYPASS STANDBY OFF
WAVEFORM SELECTION
RESET ECU/LGX
REBOOT LCP
SWITCH
↑
SELECT
↓
STATUS
ILS 420 LLZ ’LLZ−420T’ 110.10MHz
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
TX 1: ON TX 2: ON
STANDBY MAIN
LOAD AERIAL
WAVEFORM 1 WAVEFORM 1
146 hrs. 145 hrs.
Monitor: −−1−− −−2−−
Executive: NORMAL NORMAL
Farfield: NORMAL NORMAL
Standby: NORMAL NORMAL
RWY: ON
MENU MONITOR ALERTS CONTROL
LOCAL
MAINTENANCE
*
control buttons (S)
Key switch
* depends on
configuration
Fig. 3−13
CONTROL select and Control window (example)
In the Control window the submenu ’Waveform Selection’ can be called using the SELECT keys S2
and/or S3 and then the key SWITCH. In the Waveform Selection window the defined waveform names
are listed, and the following button definitions are used:
S1
SWITCH
to switch selected item to on/off;
if once used, the STATUS field indication in the display shows the new state.
S2
↑
to select item, upwards
S3
↓
to select item, downwards
S4
STATUS
to return to the Status window (see Fig. 3−6)
NOTE: After reset, WAVEFORM1 is the default setting, i.e. it should be defined as standard waveform.
1
4
2
3
1
4
2
3
CONTROLS STATUS
−−−−−−−−− −−−−−−−−
TX 1 ON
TX 2 ON
TX AERIAL 1
MON BYPASS EXE OFF
MON BYPASS STANDBY OFF
> WAVEFORM SELECTION
RESET ECU/LGX
REBOOT LCP
SWITCH
↑
SELECT
↓
STATUS
control buttons (S)
WAVEFORM SELECTION OF TX 1
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
WAVEFORM1: Standard
WAVEFORM2: Waveform 2
WAVEFORM3: Waveform 3
WAVEFORM4: Waveform 4
WAVEFORM5: Waveform 5
WAVEFORM6: Waveform 6
WAVEFORM7: Waveform 7
WAVEFORM8: Waveform 8
CURRENTLY ACTIVE: Standard
SWITCH
↑
SELECT
↓
STATUS
1.
2.
Fig. 3−14
Waveform Selection select and Waveform Selection window (example)
Summary of Contents for 421
Page 2: ......
Page 26: ...LLZ 421 General Operation and Maintenance ILS 420 1 6 Ed 01 04 SOAC ...
Page 54: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 26 Ed 01 04 SOAC Ed 01 10 ...
Page 56: ......
Page 58: ......
Page 66: ...LLZ 421 Installation Operation and Maintenance ILS 420 2 38 Ed 01 10 SOAC ...
Page 90: ...LLZ 421 Operation Operation and Maintenance ILS 420 3 24 Ed 01 10 SOAC ...
Page 148: ...LLZ GP Maintenance Operation and Maintenance ILS 420 TEST DATA SHEET 6 8 Ed 01 10 SOAC ...
Page 156: ...LLZ 421 Maintenance Operation and Maintenance ILS 420 6 14 Ed 01 10 SOAC ...
Page 216: ...LLZ 421 Alignment Procedure LLZ 1F LPD Operation and Maintenance ILS 420 7 8 Ed 07 08 SOAC ...
Page 238: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 8 Ed 07 08 SOAC ...
Page 256: ...LLZ 421 Alignment Procedure LLZ 2F LPD Operation and Maintenance ILS 420 8 26 Ed 07 08 SOAC ...