Main Programming Mode
Calibration Modes for Input and Output
Code 1 – Display Configuration
Code 2 – CH1 Measurement Task & Sampling Rate
Code 3 – CH1 Post Processing & Serial Mode Functions
Code 4 – CH2 Measurement Task & Sampling Rate
Code 5 – CH3 Functions
Code 6 – CH4 Functions
Code 7 – Result Processing
Code 8 – Data Logging & Print Mode
Code 9 – Functions for Digital Input Pins
[CAL]
[CodE_1]
[CodE_2]
[CodE_3]
[CodE_4]
[CodE_5]
[
CodE_6]
[CodE_7]
[CodE_8]
[CodE_9]
Display Brightness
[bri]
The meter’s programming codes are divided into two modes:
the
main programming mode
, and the
setpoint program-
ming mode
(See
diagram
below).
Each mode is accessible from the operational display.
Setpoint Programming Mode
The setpoint programming mode provides access to program
all setpoint and relay functions.
Code 10 – Bargraph Setup
[CodE10]
Code 10 applies to Tiger 320 Series meters with bargraph
displays only. See user manuals for DI-50EB51, DI-50TB51,
FI-B101D50E, and FI-B101D50T.
SP1
SP3
SP4
SP5
SP6
SP2
F1
F2
P
Operational Display
SP1
SP3
SP4
SP5
SP6
SP2
F1
F2
P
Operational Display
P
P
P
P
P
P
P
P
P
P
P
P
P
Setpoint Programming Mode
Setpoint 1
[SP_1]
Setpoint Activation Values Mode
Setpoint 2
[SP_2]
Setpoint 3
[SP_3]
Setpoint 4
[SP_4]
Setpoint 5
[SP_5]
Setpoint 6
[SP_6]
Enter these menus to adjust
SP activation values
Setpoint & Relay Control Settings Mode
P
P
P
P
P
Setpoint 1
[SPC_1]
Setpoint 2
[SPC_2]
Setpoint 3
[SPC_3]
Setpoint 4
[SPC_4]
Setpoint 5
[SPC_5]
Setpoint 6
[SPC_6]
Enter these menus to config-
ure SP control values
P
P
P
P
P
P
The
Setpoint
and Relay
C o n t r o l
S e t t i n g s
diagram on
Pages 34 and
35 shows the
three digit
configuration
settings that
are applied
individually to
each setpoint.
See Page 33
for an example
procedure to
configure a set-
point for simple
relay functions.
Main Programming Mode
The main programming mode provides access to program all
meter functions, except setpoints.
Front Panel Programming Codes
To enter or exit the Main
Programming Mode, press
P
and
at the same time
To enter or exit the Setpoint
Programming Mode, press
P
and
at the same time
To save a new setpoint
configuration setting and
return to the operation-
al display at any point,
press the
P
button once.
Then press the
P
and
button at the same
time to exit.
Save SP Settings & Exit
To save a new main pro-
gramming mode configu-
ration setting and return to
the operational display at
any point, press the
P
but-
ton once.
Then press the
P
and
button at the same time
to exit.
Save Code Settings & Exit
Programming Tip
The easiest and fastest way to configure the
Tiger 320 is to use a PC with the free download-
able configuration utility program.
Programming Tip
Programming Tip