Page 21
Apr-21-2016 DI-602A 320 DS (NZ313)_UL_April 2016
Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
To Step 7
From Step 6
Step 1
Step 2
Step 3
Step 4
Step 5
Step 7
Step 8
Step 9
Pass Brightness Mode
and Calibration
Modes and enter
Code 1
Set Code 1 to [X71]
Exit Code 2. Return to
Operational Display
Select [X0X] to leave
Code 1
Save Last Digit Text
Character setting
CONFIGURE
1st Digit = X Not relevant
2nd Digit = 7 Selects
text character mode
3rd Digit = 1 Selects
Channel 1
Enter Brightness Mode
LAST DIGIT
0
Result
1 Channel 1
2 Channel 2
3 Channel 3
4 Channel 4
5 Default Display
6 Total 1
7 Total 2
TEXT CHARACTER
Select Text Character
[C] from the options
listed in the diagram
above
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Operational Display
Press
at same
time
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Press
2
OR
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Press
1
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
OR
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Press
1
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Press
at same
time
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Operational Display
OR
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Step 6
Example
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Press
1
The following example procedure describes how to select the
last digit text character.
Example Procedure:
Configure the Channel 1 with C as its last digit text character
(for °C) by setting Code 1 to [
X71
] to enter the Select Last Digit
Text Character Mode. See diagram opposite.
Configure Last Digit Text Character Procedure
START HERE
Initial Setup Procedures
[CodE_1] - Display Configuration continued
Use the
button to cycle through the
m e n u ,
and the
button to cycle back.
Select Last Digit Text Character