FUNC_SMPS Registers
40
SLVUAH1C – June 2015 – Revised April 2017
Copyright © 2015–2017, Texas Instruments Incorporated
Register Descriptions
3.3.17 SMPS_THERMAL_STATUS Register (Address = 148h) [reset = 0h]
SMPS_THERMAL_STATUS is shown in
and described in
.
Return to
SMPS Thermal status register.
RESET register domain: POR
Figure 3-31. SMPS_THERMAL_STATUS Register
7
6
5
4
3
2
1
0
RESERVED
SMPS5
RESERVED
RESERVED
SMPS3
RESERVED
RESERVED
SMPS12
R-0h
R-0h
R-0h
R-0h
R-0h
R-0h
R-0h
R-0h
Table 3-34. SMPS_THERMAL_STATUS Register Field Descriptions
Bit
Field
Type
Reset
Description
7
RESERVED
R
0h
6
SMPS5
R
0h
0: SMPS5 Thermal measurement is below the limit (SMPS is
functional)
1: SMPS5 Thermal measurement is over the limit (see specification)
5
RESERVED
R
0h
4
RESERVED
R
0h
3
SMPS3
R
0h
0: SMPS3 Thermal measurement is below the limit (SMPS is
functional)
1: SMPS3 Thermal measurement is over the limit (see specification)
2
RESERVED
R
0h
1
RESERVED
R
0h
0
SMPS12
R
0h
0: SMPS12 Thermal measurement is below the limit (SMPS is
functional)
1: SMPS12 Thermal measurement is over the limit (see