FUNC_SMPS Registers
29
SLVUAH1C – June 2015 – Revised April 2017
Copyright © 2015–2017, Texas Instruments Incorporated
Register Descriptions
3.3.6 SMPS2_VOLTAGE Register (Address = 127h) [reset = X]
SMPS2_VOLTAGE is shown in
and described in
Return to
SMPS2 DVS register. Voltage to apply to the resource when it is not a DVS force command
(OTP_Config).
RESET register domain: SWORST
Figure 3-20. SMPS2_VOLTAGE Register
7
6
5
4
3
2
1
0
RANGE
VSEL
R/W-X
R/W-X
Table 3-23. SMPS2_VOLTAGE Register Field Descriptions
Bit
Field
Type
Reset
Description
7
RANGE
R/W
X
Range of the VSEL voltage. This bit is applied to
SMPS2_VOLTAGE.VSEL
0: 0.5V to 1.65V
1: 1.0 to 3.3V
Note:RANGE bit is RO when SMPS2 is ON, RANGE bit is RW when
SMPS2 is OFF
6-0
VSEL
R/W
X
See VSEL cross table showed in SMPS1_VOLTAGE.VSEL register.